New Launch - India Real Estate Report 2026.

NS SQUARE

FORTUNE BUILDERS & DEVELOPERS

UPPARPALLY

RERA approved

Approved

16th Oct 2024

Completion pending

Pending

15th Oct 2027

Registration No.

P00700009140

Project Type

Residential

Approving Authority

DTCP

District

Ranga Reddy

Taluka

Village/City/Town

State

Telangana

Project Details

Registration No.P00700009140
Certificate No.P00700009140
Project StatusNew Project
Project TypeResidential
Authority NameDTCP
Plan Approval No.Project Name
Proposed Completion2027-10-15
DistrictRanga Reddy
MandalVillage/City/Town
StreetYELLANDU ROAD
LocalityUPPARPALLY
Pin Code500030
Last Modified2025-12-13

Land Details

Sy.No./TS No.175/1/C/1, 174/2/3, 174/2/1/1, 174/1/C/1, 173/3/1/2, 173/2/3, 174/2/2, 173/3/1/1/1, 173/3/1/1/2
Plot No./House No.OPEN LAND
Total Area (sqmts)4339.28
Net Area (sqmts)4339.28
Total Building Units2
Approved Built-up Area11554.38
Boundaries East12 MT WIDE EXISTING ROAD
Boundaries WestOTHERS LAND
Boundaries NorthOTHERS LAND
Boundaries SouthOTHERS LAND

Parking

NS SQUAREPURUSHOTHAM LOYA
NS SQUARE_1MANUKONDA KRISHNA REDDY
NS SQUARE_2NARAYAN PRASAD ASAWA
NS SQUARE_3SHARAD KUMAR MARDA
NS SQUARE_4THALLADI VIJAY KUMAR

Amenities

FacilityAvailable% CompletedStatus
Open Parking (In sqmts)233200
Covered Parking ( In Numbers)9000

Unit Details

Sr.No.FloorMortgageApartment TypeSaleable Area (sqm)No. of ApartmentsNo. Booked
11False3 BHK115.6610
21False3 BHK115.6610
31False3 BHK115.6610
41False3 BHK115.6610
51False3 BHK111.4810
61False3 BHK114.7310
71False3 BHK114.7310
81False3 BHK114.7310
91False3 BHK114.7310
101False3 BHK136.1010
112True3 BHK115.6610
122True3 BHK115.6610
132True3 BHK115.6610
142True3 BHK115.6610
152True3 BHK111.4810
162True3 BHK114.7310
172True3 BHK114.7310
182True3 BHK114.7310
192True3 BHK114.7310
202True3 BHK136.1010
213True3 BHK115.6610
223False3 BHK115.6610
233False3 BHK115.6610
243False3 BHK115.6610
253False3 BHK111.4810
263False3 BHK114.7310
273False3 BHK114.7310
283False3 BHK114.7310
293False3 BHK114.7310
303False3 BHK136.1010
314False3 BHK115.6610
324False3 BHK115.6610
334False3 BHK115.6610
344False3 BHK115.6610
354False3 BHK111.4810
364False3 BHK114.7310
374False3 BHK114.7310
384False3 BHK114.7310
394False3 BHK114.7310
404False3 BHK136.1010
415False3 BHK115.6610
425False3 BHK115.6610
435False3 BHK115.6610
445False3 BHK115.6610
455False3 BHK111.4810
465False3 BHK114.7310
475False3 BHK114.7310
485False3 BHK114.7310
495False3 BHK114.7310
505False3 BHK136.1010
11False3 BHK110.0910
21False3 BHK110.0910
31False3 BHK110.0910
41False3 BHK105.0910
51False3 BHK114.7310
61False3 BHK114.7310
71False3 BHK114.7310
81False3 BHK136.1010
92False3 BHK110.0910
102False3 BHK110.0910
112False3 BHK110.0910
122False3 BHK105.0910
132False3 BHK114.7310
142False3 BHK114.7310
152False3 BHK114.7310
162False3 BHK136.1010
173False3 BHK110.0910
183False3 BHK110.0910
193False3 BHK110.0910
203False3 BHK105.0910
213False3 BHK114.7310
223False3 BHK114.7310
233False3 BHK114.7310
243False3 BHK136.1010
254False3 BHK110.0910
264False3 BHK110.0910
274False3 BHK110.0910
284False3 BHK114.7310
294False3 BHK136.1010
304False3 BHK105.9010
314False3 BHK114.7310
324False3 BHK114.7310
335False3 BHK110.0910
345False3 BHK105.9010
355False3 BHK114.7310
365False3 BHK114.7310
375False5 BHK114.7310
385False3 BHK136.1010
395False3 BHK114.7310
405False3 BHK136.1010

Professionals

NameCertificate No.Role
1Excavation95
2X number of Basement(s) and Plinth90
3X number of Podiums60
4Stilt Floor0
5X number of Slabs of Super Structure0
6Internal walls, Internal Plaster, Floorings within Flats/Premises, Doors and Windows to each of the Flat/Premises0
7Sanitary Fittings within the Flat/Premises,Electrical Fittings within the Flat/Premises0
8Staircases, Lifts Wells and Lobbies at each Floor level connecting Staircases and Lifts, Overhead and Underground Water Tanks.0
9The external plumbing and external plaster, elevation, completion of terraces with waterproofing of the Building/Wing0
10Installation of lifts, water pumps, Fire Fighting Fittings and Equipment as per CFO NOC, Electrical fittings to Common Areas, electro, mechanical equipment, Compliance to conditions of environment /CRZ NOC, Finishing to entrance lobby/s, plinth protection, paving of areas appurtenant to Building/Wing, Compound Wall and all other requirements as may be required to Obtain Occupation /Completion Certificate0
11Overall Percentage of Completion of the work done For the entire Building /Wing24.5

The information provided on this page is collated from publicly available resources. PropTech Pulse does not guarantee the accuracy, completeness, or authority of this data and shall not be held liable for any discrepancies. For queries or further assistance, please contact us at pulse@aurumproptech.in

Top Properties in Warangal

Pexo Icon

Ask Pulse Ai anything about real estate

Unlock the Latest in Real Estate

News, Infographics, Blogs & More! Delivered to your inbox.

Proptech Pulse Logo

Data that drives action.
Insight that inspires action.
Technology that empowers action.“

Made with Love

Statue

© PropTech Pulse 2026, All rights reserved.

Terms of Use and Privacy Policy