THE ROYAL RIDGE
AVSM BUILDERS
KARMANGHAT
Approved
18th Sept 2020
Completed
18th Sept 2025
Registration No.
P02200002708
Project Type
Residential
Approving Authority
HMDA
District
Ranga Reddy
Taluka
Village/City/Town
State
Telangana
Project Details
| Registration No. | P02200002708 |
| Certificate No. | P02200002708 |
| Project Status | Completed |
| Project Type | Residential |
| Authority Name | HMDA |
| Plan Approval No. | 033699/GHT/R1/U6/HMD |
| Proposed Completion | 2025-09-18 |
| District | Ranga Reddy |
| Mandal | Village/City/Town |
| Street | UPPAL BHAGAT |
| Locality | KARMANGHAT |
| Pin Code | 500079 |
| Last Modified | 2024-07-24 |
Land Details
| Sy.No./TS No. | 1 TO 40, 282 TO 368, 369/P, 370 TO 373, 374/P, 375 TO 387, 395 TO 401, 454, 456 TO 459, 505/P, 510 TO 564 |
| Plot No./House No. | 228 AND 229 |
| Total Area (sqmts) | 1673.11 |
| Net Area (sqmts) | 1673.11 |
| Total Building Units | 1 |
| Approved Built-up Area | 3909.20 |
| Mortgage Area | 407.52 |
| Boundaries East | PLOT NO 227 |
| Boundaries West | PLOT NO 230 |
| Boundaries North | PLOT NO 236 AND 237 |
| Boundaries South | ROAD WIDTH 24 |
Parking
| Open Parking (In sqmts) | 0 |
| Covered Parking ( In Numbers) | 51 |
Amenities
| Facility | Available | % Completed | Status |
|---|---|---|---|
| Internal Roads & Footpaths : | NO | 0 | NA |
| Water Supply : | YES | 50 | |
| Sewerage (Chamber, Lines, Septic Tank , STP) : | YES | 100 | |
| Storm Water Drains : | NO | 0 | NA |
| Green Strip/TOT LOT/Park : | YES | 0 | YET TO START |
| Street Lighting : | NO | 0 | NA |
| Community Buildings : | NO | 0 | NA |
| Treatment And Disposal Of Sewage And Sullage Water : | NO | 0 | NA |
| Solid Waste Management And Disposal : | NO | 0 | NA |
| Water Conservation, Rain water Harvesting : | YES | 100 | |
| Energy management : | NO | 0 | NA |
| Fire Protection And Fire Safety Requirements : | NO | 0 | NA |
| Electrical Meter Room, Sub-Station, Receiving Station : | YES | 50 | 0 |
| Aggregate area of recreational Open Space : | NO | 0 | NA |
Unit Details
| Sr.No. | Floor | Mortgage | Apartment Type | Saleable Area (sqm) | No. of Apartments | No. Booked |
|---|---|---|---|---|---|---|
| 1 | 1 | False | 3BHK | 178.44 | 1 | 0 |
| 2 | 1 | False | 3BHK | 178.83 | 1 | 0 |
| 3 | 1 | False | 3BHK | 185.80 | 1 | 1 |
| 4 | 1 | False | 3BHK | 185.80 | 1 | 1 |
| 5 | 1 | False | 3BHK | 185.80 | 1 | 1 |
| 6 | 2 | True | 3BHK | 190.52 | 1 | 0 |
| 7 | 2 | True | 3BHK | 178.44 | 1 | 0 |
| 8 | 2 | True | 3BHK | 179.83 | 1 | 0 |
| 9 | 2 | False | 3BHK | 185.80 | 1 | 1 |
| 10 | 2 | False | 3BHK | 185.80 | 1 | 1 |
| 11 | 3 | False | 3BHK | 178.44 | 1 | 0 |
| 12 | 3 | False | 3BHK | 178.83 | 1 | 0 |
| 13 | 3 | False | 3BHK | 191.91 | 1 | 0 |
| 14 | 3 | False | 3BHK | 185.80 | 1 | 1 |
| 15 | 3 | False | 3BHK | 185.80 | 1 | 1 |
| 16 | 4 | False | 3BHK | 191.91 | 1 | 0 |
| 17 | 4 | False | 3BHK | 185.80 | 1 | 1 |
| 18 | 4 | False | 3BHK | 185.80 | 1 | 1 |
| 19 | 4 | False | 3BHK | 185.80 | 1 | 1 |
| 20 | 4 | False | 3BHK | 185.80 | 1 | 1 |
| 21 | 5 | False | 3BHK | 178.83 | 1 | 0 |
| 22 | 5 | False | 3BHK | 191.91 | 1 | 0 |
| 23 | 5 | False | 3BHK | 185.80 | 1 | 1 |
| 24 | 5 | False | 3BHK | 185.80 | 1 | 1 |
| 25 | 5 | False | 3BHK | 185.80 | 1 | 1 |
Construction Progress
| Sr.No. | Task/Activity | % Completed |
|---|---|---|
| 1 | Excavation | 100 |
| 2 | X number of Basement(s) and Plinth | 100 |
| 3 | X number of Podiums | 0 |
| 4 | Stilt Floor | 100 |
| 5 | X number of Slabs of Super Structure | 100 |
| 6 | Internal walls, Internal Plaster, Floorings within Flats/Premises, Doors and Windows to each of the Flat/Premises | 100 |
| 7 | Sanitary Fittings within the Flat/Premises,Electrical Fittings within the Flat/Premises | 50 |
| 8 | Staircases, Lifts Wells and Lobbies at each Floor level connecting Staircases and Lifts, Overhead and Underground Water Tanks. | 100 |
| 9 | The external plumbing and external plaster, elevation, completion of terraces with waterproofing of the Building/Wing | 100 |
| 10 | Installation of lifts, water pumps, Fire Fighting Fittings and Equipment as per CFO NOC, Electrical fittings to Common Areas, electro, mechanical equipment, Compliance to conditions of environment /CRZ NOC, Finishing to entrance lobby/s, plinth protection, paving of areas appurtenant to Building/Wing, Compound Wall and all other requirements as may be required to Obtain Occupation /Completion Certificate | 50 |
Professionals
| Name | Certificate No. | Role |
|---|---|---|
| SUNEEL KUMAR THOTA | NA | Structural Engineer |
| KIRAN KUMAR MUPPANA | NA | Architect |
The information provided on this page is collated from publicly available resources. PropTech Pulse does not guarantee the accuracy, completeness, or authority of this data and shall not be held liable for any discrepancies. For queries or further assistance, please contact us at pulse@aurumproptech.in
Top Properties in Hyderabad


Ask Pulse Ai anything about real estate





